Pipmed Medical Pipmed Medical

Xdf50kw Medical Dr Machine Dynamic Digital Radiography and Fluoroscopy System

Still deciding? Get samples of $ !
Request Sample

Product Description

Basic Specifications
Model NO.
XDF50KW
Power Output
50kw
Current
10-630mA
Voltage
40kv-150kv
mAs
0.1-630mas
Exposure Time
1-6300ms
Focus Size
0.6/1.2
Detector Type
Flat Panel Detector
Vision Size
17X17
A/D Conversion
16 Bits
Spatial Resolution
3.6 Lp/mm
Origin
China
HS Code
90185000
Production Capacity
100
Product Description
Dynamic Digital Radiography System Header
XDF50KW Dynamic Digital Radiography/Fluoroscopy System
50kW Power Output
High-Performance X-ray Tube
Motor-driven Radiography/Fluoroscopy Table
Precision Collimator
All-in-one PC Workstation
Advanced Dynamic Flat Panel Detector
Professional Image Processing Software
Integrated Grid System
XDF50KW System Overview
Detail 1
Detail 2
Detail 3
Detail 4
Detail 5
Detail 6
Technical Comparison Data
Technical Data XDF50KW XDF65KW XDF80KW
Power Output50kW65kW80kW
Current10-630mA10-800mA10-1000mA
Voltage40kV-150kV40kV-150kV40kV-150kV
mAs0.1-630mAs0.1-800mAs0.1-1000mAs
Exposure time1-6300ms1-6300ms1-6300ms
Focus Size0.6/1.20.6/1.20.6/1.2
Detector TypeDynamic Flat Panel Detector
Vision Size17*17"
A/D Conversion16 bits
Spatial Resolution3.6 lp/mm
Pixel Size3072X3072
Maximum fps30
Facility & Quality Standards
Radiology Catalog
Production Facility
Factory Environment
Product Range
Certificates & Team
Quality Certificates
Professional Team
Frequently Asked Questions
Q: What is the primary use of the XDF50KW system? A: The XDF50KW is a versatile system designed for both Dynamic Digital Radiography and Fluoroscopy, allowing for high-definition imaging of various anatomical structures.
Q: What type of detector technology does this system utilize? A: It utilizes a 17x17 inch Dynamic Flat Panel Detector with 16-bit A/D conversion and a 3072x3072 pixel size for superior image clarity.
Q: Is the examination table motorized? A: Yes, the system includes a motor-driven radiography/fluoroscopy table to facilitate easy and precise patient positioning during examinations.
Q: What is the spatial resolution of the XDF50KW? A: The system provides a high spatial resolution of 3.6 lp/mm, ensuring detailed visualization for diagnostic accuracy.
Q: Can the power output be upgraded? A: While the XDF50KW features a 50kW output, the series also offers XDF65KW (65kW) and XDF80KW (80kW) models to suit different clinical requirements.
Q: What is the maximum frame rate for dynamic imaging? A: The system supports dynamic imaging with a maximum of 30 frames per second (fps).

Related Products