Pipmed Medical Pipmed Medical

Cbct Digital Dental X-ray Machine Msldx16dental Diagnostic Imaging Equipment

Still deciding? Get samples of $ !
Request Sample

Product Description

Technical Overview
Model
DX16
Scale
Large
Material
Acrylic, Metal, Plastic
Classification
Class II
Safety Standard
GB2626-2006
Product Name
CBCT Dental X-ray
Kvp Voltage
60-100kv
X-ray Tube Current
2-10mA
Max Exposure Power
600W
CT Sensor Type
Csi+CMOS Flat Panel Detector
Warranty
1 Year
Frequency
50kHz
Product Description

Experience the pinnacle of dental imaging with the High Quality Frequency Panoramic & CBCT Digital Dental X-ray Machine. This state-of-the-art equipment is designed for precision and excellence in dental imaging.

Utilized for capturing both dental panoramic and cephalometric images, this machine provides clear and precise digital images directly, enhancing diagnostic accuracy.

🎯

Customizable flexible field-of-view 2D imaging options for comprehensive diagnostics.

💎

Equipped with top-tier configurations and cutting-edge technology to deliver superior quality images.

🛡️

Incorporates a true MAR correction module to effectively remove metal artifacts.

☢️

Specially designed to minimize radiation doses, prioritizing patient safety.

🔄

Offers a robust data sharing function for seamless collaborative care.

CBCT Digital Dental X-ray Machine Diagnostic Imaging
Technical Specifications
Parameter Specification (MSLDX16)
X-ray Tube Voltage 60-100kV
Power supply AC 220V±10%, 50Hz, 1KVA
X-ray Tube Current 2-10mA
Max Exposure Power 600W
CT Sensor Type CsI+CMOS Flat Panel Detector
CT Field of View (D * H) 15cm x 8cm / 12cm x 8cm / 8cm x 8cm / 5cm x 5cm
CT Voxel Size 0.25mm / 0.125mm / 0.1mm / 0.075mm
CT Spatial Resolution 2.0 lp/mm
CT Scan Time 15s
CT Reconstruction Time 15s ~ 40s
Pan Sensor Pixel Size 0.1mm
Pan Exposure Time 6s ~ 11s
Visual Presentation
Frequently Asked Questions
What imaging modes does the MSLDX16 support?
The machine is versatile, supporting both high-definition panoramic and cephalometric imaging, as well as full 3D CBCT scans.
How does the MAR module improve image quality?
The True Metal Artifact Reduction (MAR) module effectively removes streaks and shadows caused by metal implants or fillings, ensuring superior clarity.
What are the available Field of View (FOV) options?
It offers multiple flexible FOV options ranging from 15cm x 8cm for broad diagnostics down to 5cm x 5cm for localized inspections.
What is the minimum voxel size for 3D scans?
The system can achieve a highly detailed voxel size of up to 0.075mm, allowing for the detection of subtle anatomical structures.
Is the radiation dose adjustable for patient safety?
Yes, the machine is specifically designed with pulsed radiation technology and adjustable parameters to minimize exposure while maintaining high image quality.
How long does a typical CT scan and reconstruction take?
A standard scan takes approximately 15 seconds, with reconstruction completed in 15 to 40 seconds depending on the selected resolution.